UPS System 20kVA
DESCRIPTION
UPS SYSTEM composed by 2 Unit that works in parallel, complete of battery charger and control of the
batteries state
NOMINAL POWER: 20 kVA
INPUT LINE: 3ph 440V 60Hz
OUTPUT LINE / POWER:
- Output 3ph 1: 115V 60Hz – 15,5 kVA
- Output 3ph 2: 115V 400Hz – 2,2kVA
- Output line 3: 24V DC – 2,5 kW
BYPASS Option (separate cabinet)
THE UNIT GUARANTEE THE FOLLOWING OUTPUT LINES IN CASE OF BOTH UPS UNITS FAULT:
- Output 3ph 1: 115V 60Hz
- Output line 3: 24V DC
DIMENSIONS
WDH [mm] 620x500x350 (without resilient)
MASS
MAX 75 Kg
MAIN PROJECT STANDARDS REFERENCES
- MIL-STD-810 (Environmental conditions)
- MIL-STD-461 (EMC)
- MIL-STD-167-1 (Vibration) – TESTED
- MIL-STD-740 (Noise)
- MIL-S-901 (Shock) – F.E.A. Analysis
COOLING SYSTEM
FORCED AIR
IP GRADE
IP56
ELECTRIC INTERFACE
TERMINAL BOARDS & GLANDS
SYSTEM
UPS SYSTEM (15-30 minutes)
Key Points
- Low magnetic signature
- Each UPS unit provides the required power rate, the system works also with only one UPS operative
Sector & Platform
- Naval 〉Minehumter
Related products
Product data sheet
Maintenance Plus
Eurocontrol offers a new and exclusive system support service directly to end users, thus obtaining many significant benefits: minimize the cost of downtime, maximize the uptime service, extend the equipments’ operational life, resolve problems independently, swiftly and effectively, balance supply and depot costs.
Do you need a taylor made solution?
Thanks to our team of highly trained and experienced application engineers, we can solve even highly complex problems.