Electro Optical Director (EOD)

DESCRIPTION
DIRECT DRIVE EOD
INPUT LINE

90Vdc (other voltage on request)
STABILIZATION ERROR
base ≤ 0,1 mrad; peak ≤ 0,3 mrad
SPEEDS AND ACCELERATIONS:

  • ELEVATION MAX SPEED 115°/s
  • ELEVATION MAX ACC 500°/s2
  • BEARING MAX SPEED 135°/s
  • BEARING MAX ACC 1000°/s2

COMMUNICATION SYSTEM
RS422 CONNECTION
AZIMUTH ANGLE RANGE: -20° +70°
TRAINING ANGLE RANGE: -172° + 172°
DIMENSIONS: [mm] 610 x 400 x 340
MASS: 62 Kg

SYSTEM COMPONENTS

  • EODCONTROLUNIT
  • EOD equipped with
  • DAY CAMERA WITH ZOOM 10X o IR camera and LRF (model TBD)

 

MAIN PROJECT STANDARDS REFERENCES:

  • MIL-STD-810 (Environmental conditions) *
  • MIL-STD-461 (EMC) *
  • MIL-STD-740 (Noise)
  • Limited MIL-S- 901 (Shock) *
  • MIL-STD-167-1 (Vibration) *

*Test performed by Certified Laboratory

IP GRADE
IP65
ELECTRIC INTERFACE
MIL CONNECTORS
SYSTEM (e.g.)

  • SURVEILLANCE
  • TRACKING SYSTEM
  • FIRE COMMAND SYSTEM


Key Points

  • Multisensors option
  • Low error during stabilization

 

Sector & Platform

 

Related products

  • Control unit
  • Day camera

Product data sheet

Maintenance Plus

Eurocontrol offers a new and exclusive system support service directly to end users, thus obtaining many significant benefits: minimize the cost of downtime, maximize the uptime service, extend the equipments’ operational life, resolve problems independently, swiftly and effectively, balance supply and depot costs.

Do you need a taylor made solution?

Thanks to our team of highly trained and experienced application engineers, we can solve even highly complex problems.